Wide operating voltage range: 4-28V
Can output 3.3V power supply
Blocking time, adjustable distance
Using special signal processing control chip RCWL-9196
Compared with the traditional infrared induction PIR, the penetration detection ability
Product description
The module has the characteristics of high sensitivity, high induction distance, high reliability, large induction angle, wide power supply voltage range, etc. it is widely used in various kinds of human body induction lighting and alarm and so on.
Product Introduction:
Operating Voltage:4-28V
Operating Current:2.8mA (typical);3mA (max)
Detection Distance:5-7m
Transmitting Power:20mW (typical);30mW (max)
Output Voltage:3.2-3.4V
Output Voltage Driving Capacity:100mA
Trigger Way: repeat trigger
Output Control Low Level:0V
Output Control High Level:3.3V
Operating Temperature:-20~80 Celsius
Storage Temperature:-40~100 Celsius
Adjustment Part Introduction:
1.C-TM
Adjust repeat trigger time, default trigger time is 2s; increasing capacitor’s capacity will make repeat trigger time longer, and actual counting trigger time can operate as below: Stick capacitor on C-TM, test 9196 3-pin frequency F, repeat trigger time T=(1/f)*32768
2.R-GN
Detection distance adjustment;connect with resistor and detection distance will become shorter;if not connect,detection distance is 7m;if connect with 1M ohm resistor,detection distance is 5m
3.R-CDS
Internal VCC parallel connect with internal 1M ohm resistor to CDS pin (that is 196 9-pin) by R-CDS, CDS connects with photoresistor, you can close detection function at night
Note: microwave modules cannot be large-scale applications in the same area, otherwise there will be mutual interference. Between single individuals over distance greater than 1M